PVX-4130 | ±6kV Pulse OutputBipolar Pulse Generator

The PVX-4130 pulse generator is optimized for high impedance capacitive loads, driving extraction grids and deflection plates, and pulsing or gating power tube grids. It generates an output voltage of 6,000 volts with rise and fall times less than 60ns, with very flat voltage pulses from 160 nanoseconds to DC into a capacitive load.

The pulse generator is a direct-coupled, air-cooled solid-state half-bridge (totem pole) design, offering equally fast pulse rise and fall times, low power dissipation, and virtually no overshoot, under-shoot or ringing. All control and protection logic circuitry, support power, energy storage and output stage circuitry are incorporated into the PVX-4130. No series or shunt resistors, impedance-matching networks between the pulser and the load, or additional energy storage (capacitor banks).

Overview

Overview 

Features

Applications

  • 0 to ±6,000 V Pulse Output
  • <60 ns Rise and Fall Times, 10 kHz Pulse Repetition Frequency
  • Protected Against Arcs, Shorts and Load Transients
  • Voltage and Current Monitor Outputs
  • Driving extraction grids and deflection plates
  • Pulsing or gating power tube grids, Pockels Cells and Q Switches, acoustic transducers, microchannel plates, pohotomultiplier tubes, and image intensifiers
Specifications 

Output

Minimal Information

±6000 Volts (Vhigh– Vlow)

Minimum Value 0 Volts
Means of Adjustment Controlled by Power Supply Input Voltages
Pulse Ride and Fall Time <60ns, typically <52ns (10% to 90%)
Pulse Width <150ns to DC, Controlled by Input Gate
Pulse Recurrence Frequency (PRF) Single shot to 10KHz at 6000V continuous output, maximum limited by power dissipation (1)
Max. Average Power 100W (Vhigh– Vlow), derated at 2W/ °C over 25 °C ambient (1)
Max. Duty Cycle Continuous
Droop <1%

Over/Undershoot

<5%
Throughout Delay 160ns Typical
Jitter <1ns shot-to-shot
Output Connector & Cable Kings 10KV, Rear Panel, with 4 feel (~1.2M) RG-58 (50Ω) Coaxial Cable

Input DC Voltage +Vin (Vhigh) (User-Supplied)

Absolute Max. Value +6000 Volts
Absolute Min. Value -6000 Volts
Relative Max. Value +6000 Volts over Vlow Voltage
Relative Min. Value +0V Over Vlow Voltage
Input DC Voltage -Vin (Vlow) (User-Supplied, only needed if biasing output)
Absolute Max. Value +6000 Volts
Asbolute Min. Value -6000 Volts
Input DC Connectors Kings 10KV, Rear Panel (One each for +Vin and -Vin)
GATE (User-Supplied)
Gate Source & Connector TTL into 50Ω, into BNC connector on the front panel
Voltage & Current Monitors
Voltage Monitor 2000: 1 into 1 MegΩ, BNC connector
Current Monitor 10A/V into 50Ω, BNC connector

General

Support Power 90VAC to 240VAC, 50/60Hz
Dimensions (Excluding Connectors) 19”W x 5.2”H x 16”D (48.25cm W x 13.2cm H x 41cm D)
Weight (Approximate) 18 lbs. (8.2 Kilograms)
***SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE***
Technical resources 

Media

Media 
Video URL 
Video title 
Determining Maximum Load capacitance for the PVX-4100 Series of High Voltage Pulse
Video URL 
Video title 
Using the PVX-4100 Series With a Single HV Input
Video URL 
Video title 
High Voltage Pulse Generators for Education
Video URL 
Video title 
High Voltage Power Supply & Pulse Generator Webinar! What You Need to Know