Our most capable current generator provides users with the ability to generate highly precise current pulses, making this unit ideal for applications that require a high level of accuracy and repeatability. Advanced safety features provide user assurance.

The Model 508 is designed for airbag and pyrotechnic initiator testing and represents the latest in current pulse generating capabilities with compelling features that provide users with time-saving characteristics of adjustability, simple operation, and programmability.

The 508 comes in a 19” 2U form factor as a 2 or 4 channel model with current sensing and resistance measurement capabilities. This unit is ideal for applications that require a high level of accuracy and repeatability.

The 508 also comes with advanced safety and testing capabilities that include remote interlock, pre/post measurements, and keyed enable switch so the unit fires only when all safety criteria are met. High functionality, safety, and a rapid return-on-investment are the hallmarks of this new fireset for pyrotechnic initiators. The Model 508 provides multiple firing channels: all-fire, no-fire, resistance measurement, DC current, capacitor discharge, Bruceton, Neyer, and high current.

The performance and advanced features of the 508 current pulse generator make it ideal for applications such as air bag deployment testing (squib detonation) or igniter deployment that can be done reliably, safely and with repeatability.

Applications such as air bag deployment testing (squib detonation), igniter triggering, or ballistics work can be done reliably, safely and with a high level of repeatability.

Overview

Overview 

Features

Applications

  • Channels: 2 or 4 Independent Channels
  • Resolution: 100 ns 
  • Accuracy: 20 ns
  • Jitter: 10 ns RMS 
  • Max Current: 6 Amps
  • Safety: Interlock and Operator Key
  • Current Generation
  • Explosive Testing
  • High Current Airbag (Squib) Testing
Features
  • 200 ns Timing Steps
  • 6 amps per Channel
  • 2 or 4 Channel Outputs
  • Benchtop or Rack Mount Design
  • Easy Programming Interface
  • TTL Sync output to T0
Advanced Features
  • Integrated 4-wire Resistance Measurement with Pre and Post-Testing features. (per channel)
    Ability to set the mean and upper/ lower limits to determine what construes a resistance fault
  • Current and Voltage Monitor Outputs.
  • Front and Rear Sync Outputs.
  • Safety features including Remote Interlock and Removable keyed enable switch.
  • RS232, USB, and optional Ethernet port for remote computer programming
Specifications 

I/O CONFIGURATION

Output Modules 2 Output Channels
4 Output Channels
Trigger Inputs Front and Rear Trigger

INTERNAL RATE GENERATOR

Rate 0.01Hz to 100 kHz
Resolution 100 ns
Accuracy 20 ns
Jitter 10 ns RMS
Output Modes Single Pulse, Burst
Burst Mode 1 to 250 pulses
Control Modes Internal Rate Generator, External Trigger

EXTERNAL TRIGGER INPUTS

Function Generate individual current pulses (single shot or burst)
Front or Rear Selectable between front or rear panel inputs
Rate DC to 1/(330ns+Longest active pulse)
Insertion Delay 330 ns
Jitter 10ns
Impedance 1kΩ
Slope Rising or Falling
Trigger Filter Filters out unwanted "glitch" or "runt" pulses
Pulse Width  0.02 us to 1 ms
Pulse Width Resolution 0.02 us
Trigger Level 2-15V
Trigger Threshold Resolution 100mV

OUTPUTS

Amplitude 0.10 - 6A
Resolution 1mA
Accuracy 2mA Typical
Compliance Voltage Level 20V
Slew Rates
Rising Edge - Inductive
(Varies with Load)
2A/ us @ 6A
1A/ us @ 3A
0.30A/ us @1A
(1 Ω and 50' cable)
Falling Edge - Inductive
(Varies with Load)
-1.60A/ us @6A
-0.90A/ us @3A
-0.30A/ us @1A
(1 ohm and 50' cable)
Rising Edge - Resistive
Varies with Load)
6.3A/ us @6A
9.5A/ us @3A
2.2A/ us @1A
(1 ohm & 2" cable)
Falling Edge - Resistive
(Varies with Load)
-5.2A/ us @6A
-4.0A/ us @3A
-1.3A/ us @1A
(1 ohm & 2" cable)

RISE TIME

Rising Edge - Inductive
Varies with Load)
4us (1 Ω, 50' cable, 6A)
Rising Edge - Resisitve
(Varies with Load)
550ns (1 Ω, 2" cable, 6A)
Pulse Width Range

5us - 100s*

(Maximum pulse width is limited by current amplitude. 1A can go up to 100 s and 6 A is limited to 300 ms.

Error ± 0.1%
Resolution 100 ns
Delay Range 0 to 1 secs
Error ± 0.1%
Resolution 100ns

MONITOR OUTPUTS

Voltage Monitor (Isolated) 1V/ V
Current Monitor 1V/A
Error < 4%
Bandwidth 150kHz

RESISTANCE MEASUREMENT

Range 0.1 to 150 Ω
Resolution .01 Ω
Error .5 to 15 Ω < 4%
Error 16 to 150 Ω < 10 %
Measurement Current 100mA (max)

SYNC OUTPUTS

Front and Rear T0, Channels A through D

SAFETY

Remote Interlock Interlock
Arming Key Switch Removable key switch

COMMUNICATION

RS232 115200, 57600, 38400, 19200, 9600, 4800 baud
USB Serial Bridge
Ethernet Option

Size

Size
19" 2Ux10" Rack Mount

Electrical

Electrical
100/240V, 50-60Hz
Downloadable Resources 

Downloadable resources such as datasheets, firmware, software, drivers and products manuals. Alternatively, you can browse resources directly by visiting our downloads page.

Product Datasheets
Product Firmware
Product Software and Drivers
Product Manuals

Media

Media 
Video URL 
Video title 
Model 508 High Current 2 and 4 Channel Pulsers
Video URL 
Video title 
Model 508 Fire Resistance Measurement Function: Pre and Post Test

Price List

Price lists are available to our registered users. To view pricing for this and other products, please log in or create a free account.